Category Archives: product range

Activ W510R Aw-meter

  • Fanless chilled mirror technology
  • Connectors for external circulation cryothermostat
  • Robust, fast, accurate
  • Very easy cleaning, limited fouling
  • User-friendly interface
  • Automated traceability with Linko PC sofware
  • Low operating costs

 

Activ W510R specifications
Technology used Chilled mirror, single-stage thermoelectric module
Measurement range Aw 0.030 à 1.000 (HRE: 0.5 à 100%)
Accuracy Aw* +/- 0.003 (HRE: +/- 0.3%)
Repeatability Aw* Standard mode : ± 0.001 (HRE: +/- 0.1%)
Precision mode : ± 0.0005 (HRE: +/- 0.05%)
Temperature control range 0°C to 50°C with external circulation cryosthermostat
Room temperature range 0°C to 50°C
Auto detect Water or solvent condensation
Sensor soiling detection
Non-volatile memory 5000 measurements
1024 product datasheets
200 users, 10 users parameters banks
Number of measurement modes Variable time : 3 (Fast, Standard, Precise)
Fixed time : 6 (Flash, 2 min … 1 hour)
Isotherms mode : 2 (consecutive temperature plateaus)
Series of measures One shot to 250 successive measurements
Measurement time Fast mode : 2 to 5 min, depending on your product
Standard mode : 3 to 10 min, depending on your product
Calibration Automatic with 14 different types of saturated / insatured salt solution or manually
A return to factory settings is possible
Dimensions W 24 cm , L 36 cm , H 18 cm
Weight 7.3 Kg without external power supply
Power consumption Active thermoregulation : < 75W/h
Inactive thermoregulation : < 15W/h
Standby : approximately 5W/h
Power requierement External, input 100-240Vac, output 12Vdc 6,25A
Consumables provided Set of 30 plastic dishes with lids
100 ml bottle of saturated salt solution
Warranty 3 years parts and labour

*control salts or homogeneous products, maintenance carried out according to recommendations

Activ W510 Aw-meter

  • Fanless chilled mirror technology
  • Robust, fast, accurate
  • Very easy cleaning, limited fouling
  • User-friendly interface
  • Automated traceability with Linko PC sofware
  • Low operating costs

 

 

Activ W510 specifications
Technology used Chilled mirror, single-stage thermoelectric module
Measurement range Aw 0.030 à 1.000 (HRE: 0.5 à 100%)
Accuracy Aw* +/- 0.003 (HRE: +/- 0.3%)
Repeatability Aw* Standard mode : ± 0.001 (HRE: +/- 0.1%)
Precision mode : ± 0.0005 (HRE: +/- 0.05%)
Room temperature range 0°C à 50°C
Auto detect Water or solvent condensation
Sensor soiling detection
Non-volatile memory 5000 measurements
1024 product datasheets
200 users, 10 users parameters banks
Number of measurement modes Variable time : 3 (Fast, Standard, Precise)
Fixed time : 6 (Flash, 2 min … 1 hour)
Isotherms mode : 2 (consecutive temperature plateaus)
Series of measures One shot to 250 successive measurements
Measurement time Fast mode : 2 to 5 min, depending on your product
Standard mode : 3 to 10 min, depending on your product
Calibration Automatic with 14 different types of saturated / insatured salt solution or manually
A return to factory settings is possible
Dimensions W 24 cm , L 36 cm , H 18 cm
Weight 7.3 Kg without external power supply
Power consumption Active thermoregulation : < 75W/h
Inactive thermoregulation : < 15W/h
Standby : approximately 5W/h
Power requierement External, input 100-240Vac, output 12Vdc 6,25A
Consumables provided Set of 30 plastic dishes with lids
100 ml bottle of saturated salt solution
Warranty 3 years parts and labour

*control salts or homogeneous products, maintenance carried out according to recommendations

Activ W810 Aw-meter

  • Fanless chilled mirror technology
  • Built-in temperature control
  • Robust, fast, accurate
  • Very easy cleaning, limited fouling
  • User-friendly interface
  • Automated traceability with Linko PC sofware
  • Low operating costs

 

Activ W810 specifications
Technology used Chilled mirror, single-stage thermoelectric module
Measurement range Aw 0.030 à 1.000 (HRE: 0.5 à 100%)
Accuracy Aw* +/- 0.003 (HRE: +/- 0.3%)
Repeatability Aw* Standard mode : ± 0.001 (HRE: +/- 0.1%)
Precision mode : ± 0.0005 (HRE: +/- 0.05%)
Temperature control range Ta – 10°C ≤ setpoint temperature ≤ Ta + 20°C
Ta = ambient temperature
Thermoregulation accuracy 0,1°C
Room temperature range 0°C à 50°C
Auto detect Water or solvent condensation
Sensor soiling detection
Non-volatile memory 5000 measurements
1024 product datasheets
200 users, 10 users parameters banks
Number of measurement modes Variable time : 3 (Fast, Standard, Precise)
Fixed time : 6 (Flash, 2 min … 1 hour)
Isotherms mode : 2 (consecutive temperature plateaus)
Series of measures One shot to 250 successive measurements
Measurement time Fast mode : 2 to 5 min, depending on your product
Standard mode : 3 to 10 min, depending on your product
Calibration Automatic with 14 different types of saturated / insatured salt solution or manually
A return to factory settings is possible
Dimensions W 24 cm , L 36 cm , H 18 cm
Weight 7.3 Kg without external power supply
Power consumption Active thermoregulation : < 75W/h
Inactive thermoregulation : < 15W/h
Standby : approximately 5W/h
Power requierement External, input 100-240Vac, output 12Vdc 6,25A
Consumables provided Set of 30 plastic dishes with lids
100 ml bottle of saturated salt solution
Warranty 3 years parts and labour

*control salts or homogeneous products, maintenance carried out according to recommendations

Activ W810D Aw-meter

  • Fanless chilled mirror technology
  • Two-stage thermoelectric module
  • Built-in temperature control
  • Robust, fast, accurate
  • Very easy cleaning, limited fouling
  • User-friendly interface
  • Automated traceability with Linko PC sofware
  • Low operating costs

 

Activ W810D specifications
Technology used Chilled mirror, two-stage thermoelectric module
Measurement range Aw 0.005 à 1.000 (HRE: 0.5 à 100%)
Accuracy Aw* +/- 0.003 (HRE: +/- 0.3%)
Repeatability Aw* Standard mode : ± 0.001 (HRE: +/- 0.1%)
Precision mode : ± 0.0005 (HRE: +/- 0.05%)
Temperature control range Ta – 10°C ≤ setpoint temperature ≤ Ta + 20°C
Ta = ambient temperature
Thermoregulation accuracy 0,1°C
Room temperature range 0°C à 50°C
Auto detect Water or solvent condensation
Sensor soiling detection
Non-volatile memory 5000 measurements
1024 product datasheets
200 users, 10 users parameters banks
Number of measurement modes Variable time : 3 (Fast, Standard, Precise)
Fixed time : 6 (Flash, 2 min … 1 hour)
Isotherms mode : 2 (consecutive temperature plateaus)
Series of measures One shot to 250 successive measurements
Measurement time Fast mode : 2 to 5 min, depending on your product
Standard mode : 3 to 10 min, depending on your product
Calibration Automatic with 14 different types of saturated / insatured salt solution or manually
A return to factory settings is possible
Dimensions W 24 cm , L 36 cm , H 18 cm
Weight 7.3 Kg without external power supply
Power consumption Active thermoregulation : < 75W/h
Inactive thermoregulation : < 15W/h
Standby : approximately 5W/h
Power requierement External, input 100-240Vac, output 12Vdc 6,25A
Consumables provided Set of 30 plastic dishes with lids
100 ml bottle of saturated salt solution
Warranty 3 years parts and labour

*control salts or homogeneous products, maintenance carried out according to recommendations

Consumables

Control and Calibration Solutions:

An Aw-meter is controlled and calibrated with saturated or unsaturated solutions of salts.

We propose different solutions of saturated salts in bottle with a screwable lid. They are made from quality laboratory salts and distilled water. Available individually.

Solutions calibrations AW

Composition:

  • total capacity 100ml, also available in 250ml
  • 70% solid powdered salts
  • 30% saturated liquid solution

Cups:

  • Plastic “disposable” but can be reused. They are equipped with a lid allowing the preservation of a sample for a few hours. Available in bundles of 30, 60, 120 or 240 units.

  • 316L stainless steel, reusable and unalterable. These cups allow a rapid heating of the sample. Available individually.

Coupelle inox AW

Syntilab Aw-meters – models


Syntilab measuring instruments are designed, developed and manufactured in France. The new Activ W510 and Activ W810 Water Activity Meters feature modern and innovative technology and are suitable for both laboratory and industrial environments.

  • Fanless chilled mirror technology
  • Single or double stage thermoelectric module
  • Built-in temperature control for the Activ W810
  • Optional connectors for external circulation cryothermostat for Activ W510
  • Robust, fast, accurate
  • Easy cleaning, limited fouling
  • User-friendly interface
  • Automated traceability with “Linko” PC software provided
  • Low operating costs

MAIN ADVANTAGES

The Activ W510 and Activ W810 models are laboratory meters that perfectly meet the quality and speed standards sought by professionals. Ideally suited for R&D and quality control environments, they are also designed to meet the needs of intensive industrial use on the production line. They are robust and require little maintenance. The technology is based on the chilled mirror principle, which is more precise, faster, more linear and more durable than other technologies.

FANLESS CHILLED MIRROR

The technology used here is patented by Syntilab. It allows fast and accurate measurements without the need for an internal ventilation system. Going fanless is a real technological advance that significantly simplifies the maintenance of a chilled mirror Aw-meter. Its implementation is based on two core elements:

  • a specific geometry and the optimization of the measuring chamber with a minimized internal volume.
  • efficient modeling of heat transfer.

The thermoelectric module for cooling the mirror can be single or double stage depending on the model. The double stage configuration allows measuring highly dehydrated products

MEASUREMENT CHAMBER

One of the main advantages of fanless technology is the limited fouling as well as a higher long-term reliability, as the measuring chamber does not include any moving parts. Its cleaning is facilitated by a direct access to the various elements without disassembly. The micro-measuring chamber as well as the cup receptacle/ dish holder are made entirely of 316L stainless steel which ensures optimum mechanical and chemical resistance, as well as recognized food compatibility. An infrared thermometer measures the temperature of the sample without contact.

THERMAL REGULATION

The Activ W810 features complete and autonomous temperature control of the sample and of the sensor with heat transfer fluid. The setpoint temperature can be set by the user in a range of -10 ° C to + 20 ° C around the ambient temperature.

Requirements for the measurement of water activity according to ISO21807
“… It is recommended to measure Aw at 25 ° C. Variations of ± 1 ° C in the actual measurement temperature have no noticeable effect on water activity … “

The Activ W510 model has no built-in temperature control but can optionally accommodate connectors for the connection of an external circulation thermostatic bath (not supplied).

The instruments can be placed directly in a cold room or in a harsh environment in a range of temperatures from 0 to 50 ° C. The 2017 instrument range benefits from a new sensor with improved thermal insulation. The quality of measurements is not affected in anyway by the proximity of an air conditioner or an oven.

USER INTERFACE

With large color LCD screens, smooth and user-friendly graphic interfaces, and high-capacity internal memories, Syntilab instruments allow optimum measurement use and traceability.

They can be connected to a computer or printer via standard USB and RS232 connectors.

While the instruments are factory-calibrated and offer excellent stability and linearity, they can be very easily controlled and recalibrated with suitable salt solutions. Recalibrations performed by the user can be cancelled if necessary.

These devices feature several modes of configurable measurement, allowing measurement times as fast as 45 seconds, as well as long analyses lasting up to ten days. They can either display Aw or ERH with a selectable 3 or 4 digit resolution. Syntilab Aw-meters are suitable for all types of situations and products, products containing large proportions of volatile substances such as alcohol or propylene glycol must be tested beforehand.

They also have an editable internal database that can store up to 1024 product sheets including the names of the products used, batch numbers and various information such as Aw limit values; water, salt or sugar contents; pH or viscosity. The contents of these sheets can be attached with the measurements made when exporting results to a computer ( see supplied software page ) or a printer.

OUR MODELS OF INSTRUMENTS
Activ W810D Activ W810 Activ W510R Activ W510